The
Gardall Safe Store
Operated by Spann Enterprises LLC |

A Secure Site
|
Gardall Fire Safe Selection
Shipped Free with 20% Off
Free Shipping Includes a Liftgate/Curbside
Delivery
You have choices with
the Gardall fire safe selection. All Gardall fire safe
models
below have a fire rating of one or two hours. The choices you have with Gardall
fire safe models are as follows:
- Chose between one
hour and two hour fire protection
- Chose a safe with
fire rating only or fire and burglary rating. All
Gardall safes are solid secure safes. But those with
a Burglary rating have extra security features which
meet criteria for insurance companies.
- Chose between
combination lock or electronic lock. The advantages
of an electronic lock are 1. quicker access 2. the
combination can be changed at any time. An
electronic lock is battery operated and a warning
light will warn you when the battery is low.
However, the batteries usually last a long time.
Also the batteries can be changed from the outside
of the safe.
Click below to read
more.
|
| FIRE RATINGS |
|
UL rating
Underwriters' Laboratories, Inc. |
for Sentry and Gardall
Fire-Resistant |
1 or 1/2 Hours UL
rating -
Class 125 or Class 150
|
Maintain an interior
temperature less than 125F or 150F and an interior relative humidity
less than 85% for class 150 or 80% for class 125, when exposed to
fire as per the Standard Time Temperature Curve for hours to 1700F.
Successfully undergo all other requirements for the Fire Endurance
Test, the Explosion Hazard Test, the Humidity Test, and the Fire
& Impact Test (separately or combined). Basically, no explosion
through 30 minutes of exposure to a 2000F fire, an immediate 30 foot
drop test, and a standard reheating for 30 minutes to 1550F. |
4 Hours UL rating -
Class 350 |
Maintain an interior
temperature less than 350F when exposed to a fire as per the
Standard Time Temperature Curve for 4 hours to 2000F. Successfully
undergo all other requirements for the Fire Endurance Test, the
Explosion Hazard Test and the Fire and Impact Test (separately or
combined). Basically, no explosion through 30 minutes of exposure to
a 2000F fire, 30 minutes of standard exposure to 1700F, and
immediate 30 foot drop test and a Standard reheating for 60 minutes
to 1700F. |
2 Hours UL rating-
Class 350 |
Maintain and interior
temperature less than 350F when exposed to a fire as per the
Standard Time Temperature Curve for 2 hours to 1850F. Successfully
undergo all other requirements for the Fire Endurance Test, the
Explosion Hazard Test, and the Fire and Impact Test (separately or
combined). Basically no explosion through 30 minutes of exposure to
a 2000F fire, 15 minutes of standard exposure to 1638F, and
immediate 30 foot drop test and a Standard reheating for 45 minutes
to 1638F. |
Can Your Business
Survive Record Losses?
Statistics show that if a company´s records are lost in
a fire, 17% can no longer furnish a financial statement,
14% suffer a reduction in credit rating and 43% go out
of business completely. No home or business is safe from
fire. Your vital records and possessions are only as
safe as the quality of protection you provide for them.
With a Gardall fire safes, you can be confident
your records will survive. |
|
|